New students: get 15% off your first order with code WELCOME15 Claim offer

admin 3 min read Nursing

[Answered]: Assign ICD-10-PCS procedure code(s) for the…

Need help with your Cardiovascular Pharmacology case study or NCLEX preparation? Connect with a verified Nursing expert now.

Assign ICD-10-PCS procedure code(s) for the following case study PROCEDURE: 1. Right femoral arterial access 2. Selective coronary angiograms 3. PTCA/stent 3.0 × 28 mm bare-metal stent proximal RCA for final reference diameter 3.30 mm 4. PTCA/stent mid RCA with 3.0 × 12 mm bare-metal stent with final reference diameter 3.30 mm 5. Left heart catheterization 6. Intra-aortic balloon pump placement DESCRIPTION OF PROCEDURE: Informed consent obtained from the patient. Written informed consent obtained from patient. Provided risk of procedure to include but not limited to bleeding, infection, hematoma, deep venous thrombosis, pulmonary embolism, limb or organ dysfunction, limb loss, kidney failure, permanent dialysis, stroke, arrhythmia, myocardial infarction, allergic reaction, respiratory complication, death. The patient was aware of risk and agreeable to proceed. The patient brought to catheterization laboratory, attached to continuous monitoring oxygen saturation, blood pressure, heart rhythm. The patient prepped sterile fashion. Right groin anesthetized 1 percent Xylocaine. Using modified Seldinger technique, micropuncture kit used to obtain access to right common femoral artery, upsized 7-French sheath, properly aspirated and flushed. JL-4 diagnostic catheter used to engage left coronary artery. Selective angiogram performed. This exchanged over the wire for JR-4 guide catheter 6-French used to engage right coronary. Selective angiogram performed in multiple views as well. Next, BMW wire was attempted to pass the RCA occlusion; however, this was not possible so this was exchanged for a pilot wire which successfully negotiated past the occlusion. Angiogram performed and wire placement was confirmed. A 2.5 × 12 balloon used to perform inflation in the proximal RCA. This was removed. Subsequent angiograms demonstrated residual stenosis. There was some size discrepancy between the proximal and mid RCA. A 3.0 × 28 mm bare-metal stent, Vision, was deployed at the lesion site and inflated to nominal pressures. TIMI 3 flow was finally obtained. In the mid to distal RCA, there was an eccentric 80 percent stenosis, so the 2.5 × 12 balloon was carefully taken past the proximal stent and positioned. This more distal lesion inflated at nominal pressures. The balloon was then removed and a 3.0 × 12 mm bare-metal stent, Vision, was positioned in the distal RCA and dilated at nominal atmospheres. This stent balloon was then removed. Next, a noncompliant 3.25 × 12 balloon was positioned within the stent margins and was inflated at pressures for a reference diameter 3.30 mm. This balloon was then removed. Next, a 3.25 × 20 noncompliant balloon was positioned within the proximal stent margins and inflated to the rated stent diameter in overlapping fashion. It should be noted the patient was on aspirin, Plavix, and Angiomax for the procedure as well as received nitroglycerin intracoronary at various times throughout the procedure. Pigtail catheter was used to perfo

Share:
Was this helpful?

Take the next step with this assignment

Every order includes a free originality report, unlimited revisions and 24/7 human support.

  • Subject expert matched to your exact course
  • Original work, written from scratch for you
  • On-time delivery, with free revisions
Purchase This Solution Order a Custom Written Paper

Secure checkout · Confidential service · No reselling